Variable Flow - Technical Specifications
| Model No. |
6x2 |
6x7 |
6x10 |
6x25 |
6x50 |
6x75 |
6x100 |
6x150 |
6x200 |
6x350 |
| Steam Capacity |
Lb/hr |
150 |
700 |
1,250 |
2,500 |
5,000 |
7,500 |
10,000 |
15,000 |
20,000 |
35,000 |
| Kg/hr |
70 |
320 |
565 |
1,130 |
2,265 |
3,400 |
4,535 |
6,800 |
9,070 |
15,875 |
Liquid Pipe Size Range (inches)
See selection chart below |
Threaded |
.75 - 1.25 |
.75 - 1.25 |
1 - 2 |
1.25 - 2.5 |
1.5 - 3 |
2 - 3 |
2.5 - 3 |
3 |
-- |
-- |
Flanged Class 125 |
-- |
-- |
-- |
-- |
-- |
4 |
4 |
4 - 6 |
4 - 8 |
4 - 8 |
| Approx Dimensions (inches) |
A |
40 |
44 |
48 |
52 |
58 |
66 |
76 |
90 |
100 |
112 |
| B |
40 |
44 |
48 |
52 |
56 |
66 |
70 |
85 |
94 |
104 |
| Shipping Weight (lbs) |
|
300 |
320 |
375 |
440 |
650 |
900 |
1,100 |
2,200 |
2,500 |
3,000 |
|
| Water Pipe Selection Chart - Choose best pipe size based on water flow rate in GPM |
| Max. GPM |
8 |
15 |
30 |
45 |
90 |
140 |
230 |
500 |
1,000 |
1,800 |
3,000 |
| Pipe Size (inches) |
.75 |
1 |
1.25 |
1.5 |
2 |
2.5 |
3 |
4 |
6 |
8 |
10 |
Technical
Specifications Heater
Diagram Request
a Brochure Submit
Application Data Sheet
 |
 |
Variable Flow Heaters are normally used on water service and are offered with cast iron housings as standard. Piping, fittings, and valves are iron, bronze, and steel. Alternate materials are available upon request. Water piping 3" dia. and smaller is threaded. 4" dia. and larger provided with 125# FF companion flanges and fittings.
|
|