Pick Direct Steam Injection Heaters
HOME ABOUT PICK ADVANTAGES OF DSI How it Works Energy Details Hot Water for Jacketed Heating INDUSTRIAL HEATERSConstant Flow Variable Flow Starch Slurry "BX" Heaters PICK PACKAGED SYSTEMS SANITARY HEATERS CUSTOM FABRICATED HEATERS CUSTOM INDIRECT HEATING DESUPERHEATER NEW INDUSTRIES SERVED Food Chemical/Pharmaceutical Pulp & Paper General Industry Wastewater and Sludge Treatment Ethanol Power FIND A REP/AGENT REQUEST SERVICE/INSTALLATION MANUALS

Lime Mud Pre-Coat Filter Showers

Direct Steam Injection HeaterA pulp mill located in Southern Georgia required 140°F wash water for the lime mud pre-coat filter. Located in the recausticizing area, the filter washes and dewaters lime prior to the lime kiln. The wash water provides both an efficient dilution wash of lime mud as well as serving to keep the filter clean, improving drainage. The customer replaced a venturi style heater for two main reasons: severe hammer to filter system piping and wide swings in discharge temperature.

 

The Solution:

Pick Direct Steam Injection 6X150-3 Constant Flow Heater
316 stainless steel construction
Normal liquid outlet assembly was deleted for easy installation and direct replacement within piping area of venturi heater.


Features and Benefits:

Smooth, Stable Operation
• Precise Temperature Control
• Low Mechanical Shear
• Compact Design
• Complete Absorption of Steam within Heater Body






ADDRESS PHONE EMAIL
730 S. INDIANA
P.O. BOX 516
WEST BEND, WI 53095
800.233.9030
262.338.1191
FAX: 262.338.8489