Regional
power plant installed two new Reverse Osmosis (R/O) systems to reduce
the amount of conventional chemical treatment for boiler feed water.
The purpose of the R/O system was to demineralize and remove impurities
in a filtered water supply via a series or bank of semi- permeable membranes.
Water at cold temperatures reduces the efficiency of the R/O system,
lessening the ability of water to pass through the membranes. A preheat
system was specified to hold incoming water at 76ºF as inlet temperature
dropped during the winter months.
The Solution:
Pick
Model 6X150-3/15 Constant Flow Direct Steam Injection Heater
The Constant Flow design, in cast iron construction, was selected to
handle the turndown requirement of the two systems. In comparison to
indirect methods of heating, the Pick Heater is the most cost effective
and simplest design. The inherent advantages of the Pick Heater came
through in a successful startup. It has been in service since the winter
of 1998.
Features and Benefits:
• Instant Supply
of Tempered Water
• Improved R/O System Efficiency
• Accurate Temperature Control
• Simple Operation
• Compact Design