Pick Direct Steam Injection Heaters
HOME ABOUT PICK ADVANTAGES OF DSI How it Works Energy Details Hot Water for Jacketed Heating INDUSTRIAL HEATERSConstant Flow Variable Flow Starch Slurry "BX" Heaters PICK PACKAGED SYSTEMS SANITARY HEATERS CUSTOM FABRICATED HEATERS CUSTOM INDIRECT HEATING DESUPERHEATER NEW INDUSTRIES SERVED Food Chemical/Pharmaceutical Pulp & Paper General Industry Wastewater and Sludge Treatment Ethanol Power FIND A REP/AGENT REQUEST SERVICE/INSTALLATION MANUALS

CIP System for Tank Cleaning

Steam injection system for CIP

A pharmaceutical company requested a complete CIP system for storage tanks. 160°F water was required at 180 PSIG for spray nozzles at a rate of 140-210 GPM. The customer wanted a complete, fully automated packaged system with caustic feed capability. The system was to include programming capability of cycle times.

 

The Solution:

A Pick 6X100-3 packaged direct steam injection heating system was installed, providing an instantaneous supply of 160°F water. A boost pump was included to increase discharge water pressure to 180 PSIG. A 20% caustic solution is metered in for final concentration of .5 - 2.0%. The system is fully automatic. The operator simply programs cycle times for hot rinse, caustic wash, and cold flush, as well as caustic concentration. The operator also has an option to bypass the program and operate any part of the sequence manually.


Features and Benefits:

Fully Automatic Operation
• Instantly Heats CIP Solution
• Single Source Supply of Packaged System